/mandos/trunk

To get this branch, use:
bzr branch http://bzr.recompile.se/loggerhead/mandos/trunk

« back to all changes in this revision

Viewing changes to debian/mandos-client.README.Debian

  • Committer: Teddy Hogeborn
  • Date: 2015-05-23 20:18:34 UTC
  • mto: This revision was merged to the branch mainline in revision 756.
  • Revision ID: teddy@recompile.se-20150523201834-e89ex4ito93yni8x
mandos: Use multiprocessing module to run checkers.

For a long time, the Mandos server has occasionally logged the message
"ERROR: Child process vanished".  This was never a fatal error, but it
has been annoying and slightly worrying, since a definite cause was
not found.  One potential cause could be the "multiprocessing" and
"subprocess" modules conflicting w.r.t. SIGCHLD.  To avoid this,
change the running of checkers from using subprocess.Popen
asynchronously to instead first create a multiprocessing.Process()
(which is asynchronous) calling a function, and have that function
then call subprocess.call() (which is synchronous).  In this way, the
only thing using any asynchronous subprocesses is the multiprocessing
module.

This makes it necessary to change one small thing in the D-Bus API,
since the subprocesses.call() function does not expose the raw wait(2)
status value.

DBUS-API (CheckerCompleted): Change the second value provided by this
                             D-Bus signal from the raw wait(2) status
                             to the actual terminating signal number.
mandos (subprocess_call_pipe): New function to be called by
                               multiprocessing.Process (starting a
                               separate process).
(Client.last_checker signal): New attribute for signal which
                              terminated last checker.  Like
                              last_checker_status, only not accessible
                              via D-Bus.
(Client.checker_callback): Take new "connection" argument and use it
                           to get returncode; set last_checker_signal.
                           Return False so gobject does not call this
                           callback again.
(Client.start_checker): Start checker using a multiprocessing.Process
                        instead of a subprocess.Popen.
(ClientDBus.checker_callback): Take new "connection" argument.        Call
                               Client.checker_callback early to have
                               it set last_checker_status and
                               last_checker_signal; use those.  Change
                               second value provided to D-Bus signal
                               CheckerCompleted to use
                               last_checker_signal if checker was
                               terminated by signal.
mandos-monitor: Update to reflect DBus API change.
(MandosClientWidget.checker_completed): Take "signal" instead of
                                        "condition" argument.  Use it
                                        accordingly.  Remove dead code
                                        (os.WCOREDUMP case).

Show diffs side-by-side

added added

removed removed

Lines of Context:
16
16
  is possible to verify that the correct password will be received by
17
17
  this client by running the command, on the client:
18
18
  
19
 
        /usr/lib/mandos/plugins.d/mandos-client \
 
19
        /usr/lib/$(dpkg-architecture -qDEB_HOST_MULTIARCH \
 
20
        )/mandos/plugins.d/mandos-client \
20
21
                --pubkey=/etc/keys/mandos/pubkey.txt \
21
22
                --seckey=/etc/keys/mandos/seckey.txt; echo
22
23
  
32
33
 
33
34
* Specifying a Client Network Interface
34
35
  
35
 
  At boot time the network interface to use will by default be
36
 
  automatically detected.  If should result in an incorrect interface,
37
 
  edit the DEVICE setting in the "/etc/initramfs-tools/initramfs.conf"
38
 
  file.  (The default setting is empty, meaning to autodetect the
39
 
  interface.)  *If* the DEVICE setting is changed, it will be
40
 
  necessary to update the initrd image by running the command
 
36
  At boot time the network interfaces to use will by default be
 
37
  automatically detected.  If this should result in incorrect
 
38
  interfaces, edit the DEVICE setting in the
 
39
  "/etc/initramfs-tools/initramfs.conf" file.  (The default setting is
 
40
  empty, meaning it will autodetect the interface.)  *If* the DEVICE
 
41
  setting is changed, it will be necessary to update the initrd image
 
42
  by running the command
41
43
  
42
44
        update-initramfs -k all -u
43
45
  
44
 
  The device can be overridden at boot time on the Linux kernel
 
46
  The device can also be overridden at boot time on the Linux kernel
45
47
  command line using the sixth colon-separated field of the "ip="
46
48
  option; for exact syntax, read the documentation in the file
47
 
  "/usr/share/doc/linux-doc-*/Documentation/filesystems/nfsroot.txt",
 
49
  "/usr/share/doc/linux-doc-*/Documentation/filesystems/nfs/nfsroot.txt",
48
50
  available in the "linux-doc-*" package.
49
51
  
50
 
  Note that since this network interface is used in the initial RAM
51
 
  disk environment, the network interface *must* exist at that stage.
52
 
  Thus, the interface can *not* be a pseudo-interface such as "br0" or
53
 
  "tun0"; instead, only real interface (such as "eth0") can be used.
 
52
  Note that since the network interfaces are used in the initial RAM
 
53
  disk environment, the network interfaces *must* exist at that stage.
 
54
  Thus, an interface can *not* be a pseudo-interface such as "br0" or
 
55
  "tun0"; instead, only real interfaces (such as "eth0") can be used.
54
56
  This can be overcome by writing a "network hook" program to create
55
 
  the interface (see mandos-client(8mandos)) and placing it in
 
57
  an interface (see mandos-client(8mandos)) and placing it in
56
58
  "/etc/mandos/network-hooks.d", from where it will be copied into the
57
59
  initial RAM disk.  Example network hook scripts can be found in
58
 
  "/usr/share/doc/mandos-client/network-hooks.d".
 
60
  "/usr/share/doc/mandos-client/examples/network-hooks.d".
59
61
 
60
62
* User-Supplied Plugins
61
63
  
89
91
  work, "--options-for=mandos-client:--connect=<ADDRESS>:<PORT>" needs
90
92
  to be manually added to the file "/etc/mandos/plugin-runner.conf".
91
93
 
92
 
 -- Teddy Hogeborn <teddy@recompile.se>, Mon, 28 Nov 2011 23:07:22 +0100
 
94
 -- Teddy Hogeborn <teddy@recompile.se>, Mon, 28 Oct 2013 11:02:26 +0100