1
1
This NEWS file records noteworthy changes, very tersely.
2
2
See the manual for detailed information.
4
Version 1.6.0 (2012-06-18)
6
** Takes new --foreground option
7
** Init script supports new "status" action.
9
** Now uses all interfaces by default; the --interface option can
10
still be used to restrict it, and the argument to --interface (as
11
well as the $DEVICE environment variable for the network hooks) is
12
now a comma-separated list of interfaces to use.
14
Version 1.5.5 (2012-06-01)
16
** Server takes new --socket option
18
Version 1.5.4 (2012-05-20)
20
** Bug fix: Regression fix: Make non-zero approval timeout values work.
21
** Bug fix: Regression fix: Allow changing the Timeout D-Bus property.
22
** Fall back to not bind to an interface if an invalid interface name
24
** Removed support for undocumented feature of using plain "%%s" in
25
"checker" client option.
26
** Old D-Bus interface are now marked as deprecated.
27
** mandos-monitor: Bug fix: show approval timers correctly.
28
** mandos-ctl: Show "Extended Timeout" correctly, not as milliseconds.
30
Version 1.5.3 (2012-01-15)
32
** Add D-Bus property se.recompile.Client.LastCheckerStatus and use it
35
** Fix bugs in the example "bridge" network hook.
37
Version 1.5.2 (2012-01-08)
39
** Removed D-Bus signal se.recompile.Mandos.NewRequest() added in
40
1.5.0. It was buggy and was of questionable utility.
42
Version 1.5.1 (2012-01-01)
44
** Include intro(8mandos) manual page, missing since migration from
45
README file in version 1.4.0.
47
Version 1.5.0 (2012-01-01)
49
** Network hooks. The Mandos client can now run custom scripts to take
50
up a network interface before the client is run. Three example
51
scripts are provided: "wireless", "openvpn", and "bridge".
52
To facilitate this, the client now prefers network interfaces which
53
are up (if any) over all other interfaces.
55
** Persistent state. Client state is now saved between server
57
** clients.conf file can now contain "enabled" setting for clients.
58
** Bug fix: Fix rare crash bug.
59
** Bug fix: Send corrent D-Bus type in PropertyChanged for
60
"ApprovalDelay", "ApprovalDuration", "Timeout", and
62
** mandos-ctl: Bare numbers as arguments are taken to be milliseconds.
63
** Bug fix: mandos-ctl --secret option now works.
64
** New D-Bus signal: se.recompile.Mandos.NewRequest(s).
66
Version 1.4.1 (2011-10-15)
68
** Make D-Bus properties settable again, and handle checkers
69
for disabled clients correctly.
70
* Miscellaneous fixes to "pedantic" Lintian warnings
72
Version 1.4.0 (2011-10-09)
73
* README file migrated to manual page intro(8mandos).
75
** Fixed warning about "rmdir: Directory not empty".
77
** Default values changed: timeout 5 minutes, interval 2 minutes.
78
** Clients gets an expiration extension when receiving a password,
79
controlled by new "extended_timeout" setting.
80
** New domain name: "fukt.bsnet.se" changes to "recompile.se". This
81
also affects the D-Bus bus and interface names (old names still
82
work). Users should start using the new names immediately.
83
** New D-Bus Client object properties "Expires" and "ExtendedTimeout";
84
see DBUS-API for details.
86
Version 1.3.1 (2011-07-27)
88
** Client now retries all Mandos servers periodically.
89
** Work around Debian bug #633582 - fixes "Permission denied" problem.
91
Version 1.3.0 (2011-03-08)
93
** Updated for Python 2.6.
95
** Bug fix: Make the password-prompt plugin not conflict with
97
** Bug fix: Bug fix: update initramfs also when purging package.
99
Version 1.2.3 (2010-10-11)
101
** Bug fix: Expose D-Bus API also in non-debug mode.
103
Version 1.2.2 (2010-10-07)
105
** splashy: Minor fix to compile with non-Linux kernels.
4
107
Version 1.2.1 (2010-10-02)
6
109
** mandos-monitor(8): Documentation bug fix: Key for removing client