/mandos/trunk

To get this branch, use:
bzr branch http://bzr.recompile.se/loggerhead/mandos/trunk

« back to all changes in this revision

Viewing changes to NEWS

  • Committer: Teddy Hogeborn
  • Date: 2012-06-22 23:33:56 UTC
  • Revision ID: teddy@recompile.se-20120622233356-odoqqt2ki2gssn37
* Makefile (check): Also check mandos-ctl.
* mandos-ctl: All options taking a time interval argument can now take
              an RFC 3339 duration.
  (rfc3339_duration_to_delta): New function.
  (string_to_delta): Try rfc3339_duration_to_delta first.
  (main): New "--check" option.
* mandos-ctl.xml (SYNOPSIS, OPTIONS): Document new "--check" option.

Show diffs side-by-side

added added

removed removed

Lines of Context:
1
1
This NEWS file records noteworthy changes, very tersely.
2
2
See the manual for detailed information.
3
3
 
 
4
Version 1.6.0 (2012-06-18)
 
5
* Server
 
6
** Takes new --foreground option
 
7
** Init script supports new "status" action.
 
8
* Client
 
9
** Now uses all interfaces by default; the --interface option can
 
10
   still be used to restrict it, and the argument to --interface (as
 
11
   well as the $DEVICE environment variable for the network hooks) is
 
12
   now a comma-separated list of interfaces to use.
 
13
 
 
14
Version 1.5.5 (2012-06-01)
 
15
* Server
 
16
** Server takes new --socket option
 
17
 
 
18
Version 1.5.4 (2012-05-20)
 
19
* Server
 
20
** Bug fix: Regression fix: Make non-zero approval timeout values work.
 
21
** Bug fix: Regression fix: Allow changing the Timeout D-Bus property.
 
22
** Fall back to not bind to an interface if an invalid interface name
 
23
   is given.
 
24
** Removed support for undocumented feature of using plain "%%s" in
 
25
   "checker" client option.
 
26
** Old D-Bus interface are now marked as deprecated.
 
27
** mandos-monitor: Bug fix: show approval timers correctly.
 
28
** mandos-ctl: Show "Extended Timeout" correctly, not as milliseconds.
 
29
 
 
30
Version 1.5.3 (2012-01-15)
 
31
* Server
 
32
** Add D-Bus property se.recompile.Client.LastCheckerStatus and use it
 
33
   in mandos-monitor.
 
34
* Client
 
35
** Fix bugs in the example "bridge" network hook.
 
36
 
 
37
Version 1.5.2 (2012-01-08)
 
38
* Server
 
39
** Removed D-Bus signal se.recompile.Mandos.NewRequest() added in
 
40
   1.5.0.  It was buggy and was of questionable utility.
 
41
 
 
42
Version 1.5.1 (2012-01-01)
 
43
* Server
 
44
** Include intro(8mandos) manual page, missing since migration from
 
45
   README file in version 1.4.0.
 
46
 
 
47
Version 1.5.0 (2012-01-01)
 
48
* Client
 
49
** Network hooks.  The Mandos client can now run custom scripts to take
 
50
   up a network interface before the client is run.  Three example
 
51
   scripts are provided: "wireless", "openvpn", and "bridge".
 
52
   To facilitate this, the client now prefers network interfaces which
 
53
   are up (if any) over all other interfaces.
 
54
* Server
 
55
** Persistent state.  Client state is now saved between server
 
56
   restarts.
 
57
** clients.conf file can now contain "enabled" setting for clients.
 
58
** Bug fix: Fix rare crash bug.
 
59
** Bug fix: Send corrent D-Bus type in PropertyChanged for
 
60
   "ApprovalDelay", "ApprovalDuration", "Timeout", and
 
61
   "ExtendedTimeout".
 
62
** mandos-ctl: Bare numbers as arguments are taken to be milliseconds.
 
63
** Bug fix: mandos-ctl --secret option now works.
 
64
** New D-Bus signal: se.recompile.Mandos.NewRequest(s).
 
65
 
 
66
Version 1.4.1 (2011-10-15)
 
67
* Server
 
68
** Make D-Bus properties settable again, and handle checkers
 
69
   for disabled clients correctly.
 
70
* Miscellaneous fixes to "pedantic" Lintian warnings
 
71
 
 
72
Version 1.4.0 (2011-10-09)
 
73
* README file migrated to manual page intro(8mandos).
 
74
* Client:
 
75
** Fixed warning about "rmdir: Directory not empty".
 
76
* Server:
 
77
** Default values changed: timeout 5 minutes, interval 2 minutes.
 
78
** Clients gets an expiration extension when receiving a password,
 
79
   controlled by new "extended_timeout" setting.
 
80
** New domain name: "fukt.bsnet.se" changes to "recompile.se".  This
 
81
   also affects the D-Bus bus and interface names (old names still
 
82
   work).  Users should start using the new names immediately.
 
83
** New D-Bus Client object properties "Expires" and "ExtendedTimeout";
 
84
   see DBUS-API for details.
 
85
 
 
86
Version 1.3.1 (2011-07-27)
 
87
* Client:
 
88
** Client now retries all Mandos servers periodically.
 
89
** Work around Debian bug #633582 - fixes "Permission denied" problem.
 
90
 
 
91
Version 1.3.0 (2011-03-08)
 
92
* Server:
 
93
** Updated for Python 2.6.
 
94
* Client:
 
95
** Bug fix: Make the password-prompt plugin not conflict with
 
96
   Plymouth.
 
97
** Bug fix: Bug fix: update initramfs also when purging package.
 
98
 
 
99
Version 1.2.3 (2010-10-11)
 
100
* Server:
 
101
** Bug fix: Expose D-Bus API also in non-debug mode.
 
102
 
 
103
Version 1.2.2 (2010-10-07)
 
104
* Client:
 
105
** splashy: Minor fix to compile with non-Linux kernels.
 
106
 
 
107
Version 1.2.1 (2010-10-02)
 
108
* Server:
 
109
** mandos-monitor(8): Documentation bug fix: Key for removing client
 
110
   is "R", not "r".
 
111
 
 
112
Version 1.2 (2010-09-28)
 
113
* Client:
 
114
** New "plymouth" plugin to ask for a password using the Plymouth
 
115
   graphical boot system.
 
116
** The Mandos client now automatically chooses a network interface if
 
117
   the DEVICE setting in /etc/initramfs-tools/initramfs.conf is set to
 
118
   the empty string.  This is also the new default instead of "eth0".
 
119
** The Mandos client --connect option now loops indefinitely until a
 
120
   password is received from the specified server.
 
121
** Bug fix: Quote directory correctly in mandos-keygen with --password
 
122
** Bug fix: don't use "echo -e" in mandos-keygen; unsupported by dash.
 
123
* Server:
 
124
** Terminology change: clients are now "ENABLED" or "DISABLED", not
 
125
   "valid" or "invalid".
 
126
** New D-Bus API; see the file "DBUS-API".
 
127
** New control utilities using the new D-Bus API:
 
128
   + mandos-ctl                A command-line based utility
 
129
   + mandos-monitor            A text-based GUI interface
 
130
** New feature: manual interactive approval or denying of clients on a
 
131
   case-by-case basis.
 
132
** New --debuglevel option to control logging
 
133
** Will not write PID file if --debug is passed
 
134
** Bug fix: Avoid race conditions with short "interval" values or
 
135
   fast checkers.
 
136
** Bug fix: Don't try to bind to a network interface when none is
 
137
   specified
 
138
 
 
139
Version 1.0.14 (2009-10-25)
 
140
Enable building without -pie and -fPIE if BROKEN_PIE is set.
 
141
 
 
142
Version 1.0.13 (2009-10-22)
 
143
* Client
 
144
** Security bug fix: If Mandos server is also installed, do not copy
 
145
   its config files (with encrypted passwords) into the initrd.img-*
 
146
   files.
 
147
 
4
148
Version 1.0.12 (2009-09-17)
5
149
* Client
6
150
** Bug fix: Allow network interface renaming by "udev" by taking down