/mandos/trunk

To get this branch, use:
bzr branch http://bzr.recompile.se/loggerhead/mandos/trunk

« back to all changes in this revision

Viewing changes to NEWS

  • Committer: Teddy Hogeborn
  • Date: 2012-05-26 22:21:17 UTC
  • mto: This revision was merged to the branch mainline in revision 591.
  • Revision ID: teddy@recompile.se-20120526222117-2n4oeb3hqyq4rjdh
* mandos: Implement "--socket" option.
  (IPv6_TCPServer.__init__): Take new "socketfd" parameter; use it.
  (MandosServer.__init__): Take new "socketfd" parameter.  Pass it on
                           to IPv6_TCPServer constructor.
  (main): Take new "--socket" option.  Also take "socket" parameter in
          "mandos.conf" configuration file.  If set, pass the value to
          MandosServer constructor.
* mandos-options.xml (socket): Document new "socket" option.
* mandos-conf.xml (OPTIONS): - '' -
* mandos.xml (SYNOPSIS, OPTIONS): Document new "--socket" option.

Show diffs side-by-side

added added

removed removed

Lines of Context:
1
1
This NEWS file records noteworthy changes, very tersely.
2
2
See the manual for detailed information.
3
3
 
 
4
Version 1.5.4 (2012-05-20)
 
5
* Server
 
6
** Bug fix: Regression fix: Make non-zero approval timeout values work.
 
7
** Bug fix: Regression fix: Allow changing the Timeout D-Bus property.
 
8
** Fall back to not bind to an interface if an invalid interface name
 
9
   is given.
 
10
** Removed support for undocumented feature of using plain "%%s" in
 
11
   "checker" client option.
 
12
** Old D-Bus interface are now marked as deprecated.
 
13
** mandos-monitor: Bug fix: show approval timers correctly.
 
14
** mandos-ctl: Show "Extended Timeout" correctly, not as milliseconds.
 
15
 
 
16
Version 1.5.3 (2012-01-15)
 
17
* Server
 
18
** Add D-Bus property se.recompile.Client.LastCheckerStatus and use it
 
19
   in mandos-monitor.
 
20
* Client
 
21
** Fix bugs in the example "bridge" network hook.
 
22
 
 
23
Version 1.5.2 (2012-01-08)
 
24
* Server
 
25
** Removed D-Bus signal se.recompile.Mandos.NewRequest() added in
 
26
   1.5.0.  It was buggy and was of questionable utility.
 
27
 
 
28
Version 1.5.1 (2012-01-01)
 
29
* Server
 
30
** Include intro(8mandos) manual page, missing since migration from
 
31
   README file in version 1.4.0.
 
32
 
 
33
Version 1.5.0 (2012-01-01)
 
34
* Client
 
35
** Network hooks.  The Mandos client can now run custom scripts to take
 
36
   up a network interface before the client is run.  Three example
 
37
   scripts are provided: "wireless", "openvpn", and "bridge".
 
38
   To facilitate this, the client now prefers network interfaces which
 
39
   are up (if any) over all other interfaces.
 
40
* Server
 
41
** Persistent state.  Client state is now saved between server
 
42
   restarts.
 
43
** clients.conf file can now contain "enabled" setting for clients.
 
44
** Bug fix: Fix rare crash bug.
 
45
** Bug fix: Send corrent D-Bus type in PropertyChanged for
 
46
   "ApprovalDelay", "ApprovalDuration", "Timeout", and
 
47
   "ExtendedTimeout".
 
48
** mandos-ctl: Bare numbers as arguments are taken to be milliseconds.
 
49
** Bug fix: mandos-ctl --secret option now works.
 
50
** New D-Bus signal: se.recompile.Mandos.NewRequest(s).
 
51
 
 
52
Version 1.4.1 (2011-10-15)
 
53
* Server
 
54
** Make D-Bus properties settable again, and handle checkers
 
55
   for disabled clients correctly.
 
56
* Miscellaneous fixes to "pedantic" Lintian warnings
 
57
 
 
58
Version 1.4.0 (2011-10-09)
 
59
* README file migrated to manual page intro(8mandos).
 
60
* Client:
 
61
** Fixed warning about "rmdir: Directory not empty".
 
62
* Server:
 
63
** Default values changed: timeout 5 minutes, interval 2 minutes.
 
64
** Clients gets an expiration extension when receiving a password,
 
65
   controlled by new "extended_timeout" setting.
 
66
** New domain name: "fukt.bsnet.se" changes to "recompile.se".  This
 
67
   also affects the D-Bus bus and interface names (old names still
 
68
   work).  Users should start using the new names immediately.
 
69
** New D-Bus Client object properties "Expires" and "ExtendedTimeout";
 
70
   see DBUS-API for details.
 
71
 
 
72
Version 1.3.1 (2011-07-27)
 
73
* Client:
 
74
** Client now retries all Mandos servers periodically.
 
75
** Work around Debian bug #633582 - fixes "Permission denied" problem.
 
76
 
 
77
Version 1.3.0 (2011-03-08)
 
78
* Server:
 
79
** Updated for Python 2.6.
 
80
* Client:
 
81
** Bug fix: Make the password-prompt plugin not conflict with
 
82
   Plymouth.
 
83
** Bug fix: Bug fix: update initramfs also when purging package.
 
84
 
 
85
Version 1.2.3 (2010-10-11)
 
86
* Server:
 
87
** Bug fix: Expose D-Bus API also in non-debug mode.
 
88
 
 
89
Version 1.2.2 (2010-10-07)
 
90
* Client:
 
91
** splashy: Minor fix to compile with non-Linux kernels.
 
92
 
 
93
Version 1.2.1 (2010-10-02)
 
94
* Server:
 
95
** mandos-monitor(8): Documentation bug fix: Key for removing client
 
96
   is "R", not "r".
 
97
 
 
98
Version 1.2 (2010-09-28)
 
99
* Client:
 
100
** New "plymouth" plugin to ask for a password using the Plymouth
 
101
   graphical boot system.
 
102
** The Mandos client now automatically chooses a network interface if
 
103
   the DEVICE setting in /etc/initramfs-tools/initramfs.conf is set to
 
104
   the empty string.  This is also the new default instead of "eth0".
 
105
** The Mandos client --connect option now loops indefinitely until a
 
106
   password is received from the specified server.
 
107
** Bug fix: Quote directory correctly in mandos-keygen with --password
 
108
** Bug fix: don't use "echo -e" in mandos-keygen; unsupported by dash.
 
109
* Server:
 
110
** Terminology change: clients are now "ENABLED" or "DISABLED", not
 
111
   "valid" or "invalid".
 
112
** New D-Bus API; see the file "DBUS-API".
 
113
** New control utilities using the new D-Bus API:
 
114
   + mandos-ctl                A command-line based utility
 
115
   + mandos-monitor            A text-based GUI interface
 
116
** New feature: manual interactive approval or denying of clients on a
 
117
   case-by-case basis.
 
118
** New --debuglevel option to control logging
 
119
** Will not write PID file if --debug is passed
 
120
** Bug fix: Avoid race conditions with short "interval" values or
 
121
   fast checkers.
 
122
** Bug fix: Don't try to bind to a network interface when none is
 
123
   specified
 
124
 
 
125
Version 1.0.14 (2009-10-25)
 
126
Enable building without -pie and -fPIE if BROKEN_PIE is set.
 
127
 
4
128
Version 1.0.13 (2009-10-22)
5
129
* Client
6
130
** Security bug fix: If Mandos server is also installed, do not copy