/mandos/trunk

To get this branch, use:
bzr branch http://bzr.recompile.se/loggerhead/mandos/trunk

« back to all changes in this revision

Viewing changes to mandos.xml

  • Committer: Teddy Hogeborn
  • Date: 2009-04-16 01:00:35 UTC
  • Revision ID: teddy@fukt.bsnet.se-20090416010035-y7ta6ra2da4gf6mp
Minor code cleanup; one minor bug fix.

* initramfs-tools-hook: Bug fix: Use the primary group of the first
                        suitable user found, do not look for a
                        group separately.
* mandos: Unconditionally import "struct" and "fcntl".  Use unicode
          strings everywhere possible.
  (Client._datetime_to_milliseconds): New static method.
  (Client.timeout_milliseconds, Client.interval_milliseconds): Use
                                                               above
                                                               method.
  (ClientDBus.CheckedOK,
  ClientDBus.Enable, ClientDBus.StopChecker): Define normally.
  (if_nametoindex): Document non-acceptance of unicode strings.  All
                    callers adjusted.  Do not import "struct" or
                    "fcntl".  Log warning message if if_nametoindex
                    cannot be found using ctypes modules.
  (main): Bug fix: Do not look for user named "nogroup".

Show diffs side-by-side

added added

removed removed

Lines of Context:
2
2
<!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.5//EN"
3
3
"http://www.oasis-open.org/docbook/xml/4.5/docbookx.dtd" [
4
4
<!ENTITY COMMANDNAME "mandos">
5
 
<!ENTITY TIMESTAMP "2009-09-10">
 
5
<!ENTITY TIMESTAMP "2009-02-15">
6
6
<!ENTITY % common SYSTEM "common.ent">
7
7
%common;
8
8
]>
327
327
      The server will, by default, continually check that the clients
328
328
      are still up.  If a client has not been confirmed as being up
329
329
      for some time, the client is assumed to be compromised and is no
330
 
      longer eligible to receive the encrypted password.  (Manual
331
 
      intervention is required to re-enable a client.)  The timeout,
 
330
      longer eligible to receive the encrypted password.  The timeout,
332
331
      checker program, and interval between checks can be configured
333
332
      both globally and per client; see <citerefentry>
334
333
      <refentrytitle>mandos-clients.conf</refentrytitle>