/mandos/release

To get this branch, use:
bzr branch http://bzr.recompile.se/loggerhead/mandos/release

« back to all changes in this revision

Viewing changes to mandos-monitor

  • Committer: Teddy Hogeborn
  • Date: 2019-08-02 22:16:53 UTC
  • mto: This revision was merged to the branch mainline in revision 386.
  • Revision ID: teddy@recompile.se-20190802221653-ic1iko9hbefzwsk7
Fix bug in server Debian package: Fails to start on first install

There has been a very long-standing bug where installation of the
server (the "mandos" Debian package) would fail to start the server
properly right after installation.  It would work on manual (re)start
after installation, or after reboot, and even after package purge and
reinstall, it would then work the first time.  The problem, it turns
out, is when the new "_mandos" user (and corresponding group) is
created, the D-Bus server is not reloaded, and is therefore not aware
of that user, and does not recognize the user and group name in the
/etc/dbus-1/system.d/mandos.conf file.  The Mandos server, when it
tries to start and access the D-Bus, is then not permitted to connect
to its D-Bus bus name, and disables D-Bus use as a fallback measure;
i.e. the server works, but it is not controllable via D-Bus commands
(via mandos-ctl or mandos-monitor).  The next time the D-Bus daemon is
reloaded for any reason, the new user & group would become visible to
the D-Bus daemon and after that, any restart of the Mandos server
would succeed and it would bind to its D-Bus name properly, and
thereby be visible and controllable by mandos-ctl & mandos-monitor.
This was mostly invisible when using sysvinit, but systemd makes the
problem visible since the systemd service file for the Mandos server
is configured to not consider the Mandos server "started" until the
D-Bus name has been bound; this makes the starting of the service wait
for 90 seconds and then fail with a timeout error.

Fixing this should also make the Debian CI autopkgtest tests work.

* debian/mandos.postinst (configure): After creating (or renaming)
                                      user & group, reload D-Bus
                                      daemon (if present).

Show diffs side-by-side

added added

removed removed

Lines of Context:
3
3
#
4
4
# Mandos Monitor - Control and monitor the Mandos server
5
5
#
6
 
# Copyright © 2009-2016 Teddy Hogeborn
7
 
# Copyright © 2009-2016 Björn Påhlsson
8
 
#
9
 
# This program is free software: you can redistribute it and/or modify
10
 
# it under the terms of the GNU General Public License as published by
 
6
# Copyright © 2009-2019 Teddy Hogeborn
 
7
# Copyright © 2009-2019 Björn Påhlsson
 
8
#
 
9
# This file is part of Mandos.
 
10
#
 
11
# Mandos is free software: you can redistribute it and/or modify it
 
12
# under the terms of the GNU General Public License as published by
11
13
# the Free Software Foundation, either version 3 of the License, or
12
14
# (at your option) any later version.
13
15
#
14
 
#     This program is distributed in the hope that it will be useful,
15
 
#     but WITHOUT ANY WARRANTY; without even the implied warranty of
 
16
#     Mandos is distributed in the hope that it will be useful, but
 
17
#     WITHOUT ANY WARRANTY; without even the implied warranty of
16
18
#     MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
17
19
#     GNU General Public License for more details.
18
20
#
19
21
# You should have received a copy of the GNU General Public License
20
 
# along with this program.  If not, see
21
 
# <http://www.gnu.org/licenses/>.
 
22
# along with Mandos.  If not, see <http://www.gnu.org/licenses/>.
22
23
#
23
24
# Contact the authors at <mandos@recompile.se>.
24
25
#
58
59
domain = 'se.recompile'
59
60
server_interface = domain + '.Mandos'
60
61
client_interface = domain + '.Mandos.Client'
61
 
version = "1.7.14"
 
62
version = "1.8.5"
62
63
 
63
64
try:
64
65
    dbus.OBJECT_MANAGER_IFACE
443
444
        self.clients_dict = {}
444
445
 
445
446
        # We will add Text widgets to this list
446
 
        self.log = []
 
447
        self.log = urwid.SimpleListWalker([])
447
448
        self.max_log_length = max_log_length
448
449
 
449
450
        self.log_level = log_level
502
503
        if self.max_log_length:
503
504
            if len(self.log) > self.max_log_length:
504
505
                del self.log[0:len(self.log)-self.max_log_length-1]
505
 
        self.logbox.set_focus(len(self.logbox.body.contents),
 
506
        self.logbox.set_focus(len(self.logbox.body.contents)-1,
506
507
                              coming_from="above")
507
508
        self.refresh()
508
509