/mandos/release

To get this branch, use:
bzr branch http://bzr.recompile.se/loggerhead/mandos/release

« back to all changes in this revision

Viewing changes to debian/mandos-client.README.Debian

  • Committer: Teddy Hogeborn
  • Date: 2019-03-30 07:03:04 UTC
  • mto: This revision was merged to the branch mainline in revision 382.
  • Revision ID: teddy@recompile.se-20190330070304-dqgch62lsaaygg46
mandos-ctl: Refactor D-Bus operations

* mandos-ctl (dbus): Rename imported module to "dbus_python".
  (main): Only create a bus object and do everything via that object.
  (get_mandos_dbus_object): Remove and move code into dbus or
                            dbus_python_adapter namespaces.
  (if_dbus_exception_log_with_exception_and_exit): - '' -
  (SilenceLogger): - '' -
  (dbus): New; move everything dbus-specific into this module-like
          namespace.
  (dbus_python_adapter): New; move everything specific to the
                         dbus-python D-Bus module into this
                         module-like namespace.
  (command.Base.run): Take only a bus argument; use only that.  Pass
                      "client" argument as a D-Bus object path string,
                      not a dbus-python proxy object.  All derivatives
                      adjusted.
  (command.IsEnabled.is_enabled): Remove.
  (command.Approve, command.Deny, command.Remove,
  command.PropertySetter): Do no logging of D-Bus commands, and use
  only bus, not client, to do D-Bus calls.
  (command.DumpJSON.dbus_boolean_to_bool): Remove; move filtering to
                                           dbus_python_adapter.
  (command.Enable, command.Disable, command.StopChecker,
  command.ApproveByDefault): Use normal Python booleans instead of
  dbus-python's special Boolean types.
  (Unique): New; move here out from inside TestPropertySetterCmd.
  (Test_get_mandos_dbus_object): Remove.
  (Test_get_managed_objects): - '' -
  (Test_dbus_exceptions): New.
  (Test_dbus_MandosBus): - '' -
  (Test_dbus_python_adapter_SystemBus): - '' -
  (Test_dbus_python_adapter_CachingBus): - '' -
  (Test_commands_from_options): Don't create mock client proxy
  objects, define dict of client properties and use a mock dbus to
  verify that the correct D-Bus calls are made.  Also remove any types
  specific to dbus-python.
  (TestEnableCmd, TestDisableCmd, TestStartCheckerCmd,
  TestStopCheckerCmd, TestApproveByDefaultCmd, TestDenyByDefaultCmd):
  Use normal Python booleans instead of dbus-python's special Boolean
  types.
  (TestPropertySetterValueCmd.runTest): Remove; unnecessary.

Show diffs side-by-side

added added

removed removed

Lines of Context:
25
25
        /usr/lib/$(dpkg-architecture -qDEB_HOST_MULTIARCH \
26
26
        )/mandos/plugins.d/mandos-client \
27
27
                --pubkey=/etc/keys/mandos/pubkey.txt \
28
 
                --seckey=/etc/keys/mandos/seckey.txt; echo
 
28
                --seckey=/etc/keys/mandos/seckey.txt \
 
29
                --tls-privkey=/etc/keys/mandos/tls-privkey.pem \
 
30
                --tls-pubkey=/etc/keys/mandos/tls-pubkey.pem; echo
29
31
  
30
32
  This command should retrieve the password from the server, decrypt
31
33
  it, and output it to standard output.  There it can be verified to
106
108
  policy or other reasons, simply replace the existing dhparams.pem
107
109
  file and update the initital RAM disk image.
108
110
 
109
 
 -- Teddy Hogeborn <teddy@recompile.se>, Tue, 21 Jun 2016 21:43:49 +0200
 
111
 -- Teddy Hogeborn <teddy@recompile.se>, Sat,  9 Feb 2019 15:08:04 +0100