/mandos/release

To get this branch, use:
bzr branch http://bzr.recompile.se/loggerhead/mandos/release

« back to all changes in this revision

Viewing changes to debian/mandos-client.postrm

* DBUS-API: Document new "Expires" and "ExtendedTimeout" properties.
* README: Refer to the installed manual page more simply.
* mandos (Client.extended_timeout, Client.expires): New attributes.
  (Client.extended_timeout_milliseconds): New.
  (Client.__init__, Client.enable, Client.disable): Set new attributes.
  (Client.checked_ok): Take new "timeout" argument.
  (ClientDBus.expires): Transform into a property which sends a D-Bus
                        signal when changed.
  (ClientDBus._datetime_to_dbus): Return empty D-Bus string on None.
                                  All callers changed to use this.

  (ClientDBus.ApprovedByDefault_dbus_property,
  ClientDBus.ApprovalDelay_dbus_property,
  ClientDBus.ApprovalDuration_dbus_property,
  ClientDBus.Host_dbus_property, ClientDBus.Timeout_dbus_property,
  ClientDBus.Interval_dbus_property,
  ClientDBus.Checker_dbus_property): Bug fix: Only send D-Bus signal
                                     if new value is different.
  (ClientDBus.Timeout_dbus_property): Use new "expires" attribute.
  (ClientDBus.Expires_dbus_property,
  ClientDBus.ExtendedTimeout_dbus_property): New D-Bus properties.
  (ClientHandler.handle): Bump time using extended_timeout value.
  (main.client_defaults): Change default values of "timeout" and
                          "interval", added new default value for
                          "extended_timeout".
* mandos-clients.conf.xml (OPTIONS): Changed default values of
                                     "interval" and "timeout".  Add
                                     new "extended_timeout" option.
  (EXAMPLE): Updated default values.
* mandos-ctl: Show new "ExtendedTimeout" D-Bus property and change it
              using new "--extended-timeout" option.
* mandos-ctl.xml (SYNOPSIS, OPTIONS): Document new
                                      "--extended-timeout" option.
* mandos-monitor (MandosClientWidget.update): Use new "Expires" D-Bus
                                              property.
* mandos.xml (DESCRIPTION): Add reference to intro(8mandos) manual
                            page.
  (CHECKING): Refer to the new "extended_timeout" option in
  clients.conf.

Show diffs side-by-side

added added

removed removed

Lines of Context:
1
 
#!/bin/sh
 
1
#!/bin/sh -e
2
2
# This script can be called in the following ways:
3
3
#
4
4
# After the package was removed:
26
26
# If preinst fails during upgrade:
27
27
#       <new-postrm> abort-upgrade <old-version>
28
28
 
29
 
set -e
30
29
 
31
30
# Update the initial RAM file system image
32
31
update_initramfs()
33
32
{
34
 
    if command -v update-initramfs >/dev/null; then
35
 
        update-initramfs -k all -u
36
 
    elif command -v dracut >/dev/null; then
37
 
        # Logic taken from dracut.postinst
38
 
        for kernel in /boot/vmlinu[xz]-*; do
39
 
            kversion="${kernel#/boot/vmlinu[xz]-}"
40
 
            if [ "$kversion" != "*" ]; then
41
 
                /etc/kernel/postinst.d/dracut "$kversion"
42
 
            fi
43
 
        done
 
33
    if [ -x /usr/sbin/update-initramfs ]; then
 
34
        update-initramfs -u -k all
44
35
    fi
45
36
}
46
37
 
53
44
        shred --remove /etc/keys/mandos/seckey.txt 2>/dev/null || :
54
45
        rm --force /etc/mandos/plugin-runner.conf \
55
46
            /etc/keys/mandos/pubkey.txt \
56
 
            /etc/keys/mandos/seckey.txt \
57
 
            /etc/keys/mandos/tls-privkey.pem \
58
 
            /etc/keys/mandos/tls-pubkey.pem \
59
 
            /etc/keys/mandos/dhparams.pem 2>/dev/null
 
47
            /etc/keys/mandos/seckey.txt 2>/dev/null
60
48
        update_initramfs
61
49
        ;;
62
50
    upgrade|failed-upgrade|disappear|abort-install|abort-upgrade)