/mandos/release

To get this branch, use:
bzr branch http://bzr.recompile.se/loggerhead/mandos/release

« back to all changes in this revision

Viewing changes to NEWS

  • Committer: Teddy Hogeborn
  • Date: 2014-06-15 02:48:49 UTC
  • mto: (237.7.272 trunk)
  • mto: This revision was merged to the branch mainline in revision 317.
  • Revision ID: teddy@recompile.se-20140615024849-68x3q8g4yzadl33s
mandos: New "--no-zeroconf" option.  Also make "--socket=0" work.

* mandos (main): New "--no-zeroconf" option.  Also do not interpret
                 socket=0 as no socket.
* mandos-options.xml (zeroconf): New.
* mandos.conf (socket, zeroconf): New.
* mandos.xml (SYNOPSIS, OPTIONS): Added "--no-zeroconf".

Show diffs side-by-side

added added

removed removed

Lines of Context:
1
1
This NEWS file records noteworthy changes, very tersely.
2
2
See the manual for detailed information.
3
3
 
 
4
Version 1.6.5 (2014-05-11)
 
5
* Client
 
6
** Work around bug in GnuPG <http://bugs.g10code.com/gnupg/issue1622>
 
7
** Give better error messages when run without sufficient privileges
 
8
** Only warn if workaround for Debian bug #633582 was necessary and
 
9
   failed, not if it failed and was unnecessary.
 
10
 
 
11
Version 1.6.4 (2014-02-16)
 
12
* Server
 
13
** Very minor fix to self-test code.
 
14
 
 
15
Version 1.6.3 (2014-01-21)
 
16
* Server
 
17
** Add systemd support.
 
18
** For PID file, fall back to /var/run if /run does not exist.
 
19
* Client
 
20
** Moved files from /usr/lib/mandos to whatever the architecture
 
21
   specifies, like /usr/lib/x86_64-linux-gnu/mandos or
 
22
   /usr/lib64/mandos.
 
23
 
 
24
Version 1.6.2 (2013-10-24)
 
25
* Server
 
26
** PID file moved from /var/run to /run.
 
27
** Bug fix: Handle long secrets when saving client state.
 
28
** Bug fix: Use more magic in the GnuTLS priority string to handle
 
29
   both old DSA/ELG 2048-bit keys and new RSA/RSA 4096-bit keys.
 
30
* Client
 
31
** mandos-keygen: Bug fix: now generate RSA keys which GnuTLS can use.
 
32
                  Bug fix: Output passphrase prompts even when
 
33
                  redirecting standard output.
 
34
 
 
35
Version 1.6.1 (2013-10-13)
 
36
* Server
 
37
** All client options for time intervals now also take an RFC 3339
 
38
   duration.  The same for all options to mandos-ctl.
 
39
** Bug fix: Handle fast checkers (like ":") correctly.
 
40
** Bug fix: Don't print output from checkers when running in
 
41
   foreground.
 
42
** Bug fix: Do not fail when client is removed from clients.conf but
 
43
   saved settings remain.
 
44
** Bug fix: mandos-monitor now displays standout (reverse video) again
 
45
   using new version of Urwid.
 
46
** Bug fix: Make boolean options work from the config file again.
 
47
** Bug fix: Make --no-ipv6 work again.
 
48
** New default priority string to be slightly more compatible with
 
49
   older versions of GnuTLS.
 
50
* Client
 
51
** Bug fix: Fix bashism in mandos-keygen.
 
52
** Default key and subkey types are now RSA and RSA, respectively.
 
53
   Also, new default key size is 4096 bits.
 
54
 
 
55
Version 1.6.0 (2012-06-18)
 
56
* Server
 
57
** Takes new --foreground option
 
58
** Init script supports new "status" action.
 
59
* Client
 
60
** Now uses all interfaces by default; the --interface option can
 
61
   still be used to restrict it, and the argument to --interface (as
 
62
   well as the $DEVICE environment variable for the network hooks) is
 
63
   now a comma-separated list of interfaces to use.
 
64
 
 
65
Version 1.5.5 (2012-06-01)
 
66
* Server
 
67
** Server takes new --socket option
 
68
 
 
69
Version 1.5.4 (2012-05-20)
 
70
* Server
 
71
** Bug fix: Regression fix: Make non-zero approval timeout values work.
 
72
** Bug fix: Regression fix: Allow changing the Timeout D-Bus property.
 
73
** Fall back to not bind to an interface if an invalid interface name
 
74
   is given.
 
75
** Removed support for undocumented feature of using plain "%%s" in
 
76
   "checker" client option.
 
77
** Old D-Bus interface are now marked as deprecated.
 
78
** mandos-monitor: Bug fix: show approval timers correctly.
 
79
** mandos-ctl: Show "Extended Timeout" correctly, not as milliseconds.
 
80
 
 
81
Version 1.5.3 (2012-01-15)
 
82
* Server
 
83
** Add D-Bus property se.recompile.Client.LastCheckerStatus and use it
 
84
   in mandos-monitor.
 
85
* Client
 
86
** Fix bugs in the example "bridge" network hook.
 
87
 
 
88
Version 1.5.2 (2012-01-08)
 
89
* Server
 
90
** Removed D-Bus signal se.recompile.Mandos.NewRequest() added in
 
91
   1.5.0.  It was buggy and was of questionable utility.
 
92
 
 
93
Version 1.5.1 (2012-01-01)
 
94
* Server
 
95
** Include intro(8mandos) manual page, missing since migration from
 
96
   README file in version 1.4.0.
 
97
 
 
98
Version 1.5.0 (2012-01-01)
 
99
* Client
 
100
** Network hooks.  The Mandos client can now run custom scripts to take
 
101
   up a network interface before the client is run.  Three example
 
102
   scripts are provided: "wireless", "openvpn", and "bridge".
 
103
   To facilitate this, the client now prefers network interfaces which
 
104
   are up (if any) over all other interfaces.
 
105
* Server
 
106
** Persistent state.  Client state is now saved between server
 
107
   restarts.
 
108
** clients.conf file can now contain "enabled" setting for clients.
 
109
** Bug fix: Fix rare crash bug.
 
110
** Bug fix: Send corrent D-Bus type in PropertyChanged for
 
111
   "ApprovalDelay", "ApprovalDuration", "Timeout", and
 
112
   "ExtendedTimeout".
 
113
** mandos-ctl: Bare numbers as arguments are taken to be milliseconds.
 
114
** Bug fix: mandos-ctl --secret option now works.
 
115
** New D-Bus signal: se.recompile.Mandos.NewRequest(s).
 
116
 
 
117
Version 1.4.1 (2011-10-15)
 
118
* Server
 
119
** Make D-Bus properties settable again, and handle checkers
 
120
   for disabled clients correctly.
 
121
* Miscellaneous fixes to "pedantic" Lintian warnings
 
122
 
 
123
Version 1.4.0 (2011-10-09)
 
124
* README file migrated to manual page intro(8mandos).
 
125
* Client:
 
126
** Fixed warning about "rmdir: Directory not empty".
 
127
* Server:
 
128
** Default values changed: timeout 5 minutes, interval 2 minutes.
 
129
** Clients gets an expiration extension when receiving a password,
 
130
   controlled by new "extended_timeout" setting.
 
131
** New domain name: "fukt.bsnet.se" changes to "recompile.se".  This
 
132
   also affects the D-Bus bus and interface names (old names still
 
133
   work).  Users should start using the new names immediately.
 
134
** New D-Bus Client object properties "Expires" and "ExtendedTimeout";
 
135
   see DBUS-API for details.
 
136
 
 
137
Version 1.3.1 (2011-07-27)
 
138
* Client:
 
139
** Client now retries all Mandos servers periodically.
 
140
** Work around Debian bug #633582 - fixes "Permission denied" problem.
 
141
 
 
142
Version 1.3.0 (2011-03-08)
 
143
* Server:
 
144
** Updated for Python 2.6.
 
145
* Client:
 
146
** Bug fix: Make the password-prompt plugin not conflict with
 
147
   Plymouth.
 
148
** Bug fix: Bug fix: update initramfs also when purging package.
 
149
 
 
150
Version 1.2.3 (2010-10-11)
 
151
* Server:
 
152
** Bug fix: Expose D-Bus API also in non-debug mode.
 
153
 
 
154
Version 1.2.2 (2010-10-07)
 
155
* Client:
 
156
** splashy: Minor fix to compile with non-Linux kernels.
 
157
 
 
158
Version 1.2.1 (2010-10-02)
 
159
* Server:
 
160
** mandos-monitor(8): Documentation bug fix: Key for removing client
 
161
   is "R", not "r".
 
162
 
 
163
Version 1.2 (2010-09-28)
 
164
* Client:
 
165
** New "plymouth" plugin to ask for a password using the Plymouth
 
166
   graphical boot system.
 
167
** The Mandos client now automatically chooses a network interface if
 
168
   the DEVICE setting in /etc/initramfs-tools/initramfs.conf is set to
 
169
   the empty string.  This is also the new default instead of "eth0".
 
170
** The Mandos client --connect option now loops indefinitely until a
 
171
   password is received from the specified server.
 
172
** Bug fix: Quote directory correctly in mandos-keygen with --password
 
173
** Bug fix: don't use "echo -e" in mandos-keygen; unsupported by dash.
 
174
* Server:
 
175
** Terminology change: clients are now "ENABLED" or "DISABLED", not
 
176
   "valid" or "invalid".
 
177
** New D-Bus API; see the file "DBUS-API".
 
178
** New control utilities using the new D-Bus API:
 
179
   + mandos-ctl                A command-line based utility
 
180
   + mandos-monitor            A text-based GUI interface
 
181
** New feature: manual interactive approval or denying of clients on a
 
182
   case-by-case basis.
 
183
** New --debuglevel option to control logging
 
184
** Will not write PID file if --debug is passed
 
185
** Bug fix: Avoid race conditions with short "interval" values or
 
186
   fast checkers.
 
187
** Bug fix: Don't try to bind to a network interface when none is
 
188
   specified
 
189
 
4
190
Version 1.0.14 (2009-10-25)
5
191
Enable building without -pie and -fPIE if BROKEN_PIE is set.
6
192