/mandos/release

To get this branch, use:
bzr branch http://bzr.recompile.se/loggerhead/mandos/release

« back to all changes in this revision

Viewing changes to NEWS

  • Committer: Teddy Hogeborn
  • Date: 2015-05-23 20:18:34 UTC
  • mto: (237.7.304 trunk)
  • mto: This revision was merged to the branch mainline in revision 325.
  • Revision ID: teddy@recompile.se-20150523201834-e89ex4ito93yni8x
mandos: Use multiprocessing module to run checkers.

For a long time, the Mandos server has occasionally logged the message
"ERROR: Child process vanished".  This was never a fatal error, but it
has been annoying and slightly worrying, since a definite cause was
not found.  One potential cause could be the "multiprocessing" and
"subprocess" modules conflicting w.r.t. SIGCHLD.  To avoid this,
change the running of checkers from using subprocess.Popen
asynchronously to instead first create a multiprocessing.Process()
(which is asynchronous) calling a function, and have that function
then call subprocess.call() (which is synchronous).  In this way, the
only thing using any asynchronous subprocesses is the multiprocessing
module.

This makes it necessary to change one small thing in the D-Bus API,
since the subprocesses.call() function does not expose the raw wait(2)
status value.

DBUS-API (CheckerCompleted): Change the second value provided by this
                             D-Bus signal from the raw wait(2) status
                             to the actual terminating signal number.
mandos (subprocess_call_pipe): New function to be called by
                               multiprocessing.Process (starting a
                               separate process).
(Client.last_checker signal): New attribute for signal which
                              terminated last checker.  Like
                              last_checker_status, only not accessible
                              via D-Bus.
(Client.checker_callback): Take new "connection" argument and use it
                           to get returncode; set last_checker_signal.
                           Return False so gobject does not call this
                           callback again.
(Client.start_checker): Start checker using a multiprocessing.Process
                        instead of a subprocess.Popen.
(ClientDBus.checker_callback): Take new "connection" argument.        Call
                               Client.checker_callback early to have
                               it set last_checker_status and
                               last_checker_signal; use those.  Change
                               second value provided to D-Bus signal
                               CheckerCompleted to use
                               last_checker_signal if checker was
                               terminated by signal.
mandos-monitor: Update to reflect DBus API change.
(MandosClientWidget.checker_completed): Take "signal" instead of
                                        "condition" argument.  Use it
                                        accordingly.  Remove dead code
                                        (os.WCOREDUMP case).

Show diffs side-by-side

added added

removed removed

Lines of Context:
1
1
This NEWS file records noteworthy changes, very tersely.
2
2
See the manual for detailed information.
3
3
 
 
4
Version 1.6.9 (2014-10-05)
 
5
* Server
 
6
** Changed to emit standard D-Bus signal when D-Bus properties change.
 
7
   (The old signal is still emitted too, but marked as deprecated.)
 
8
 
 
9
Version 1.6.8 (2014-08-06)
 
10
* Client
 
11
** Bug fix: mandos-keygen now generates working SSH checker commands.
 
12
* Server
 
13
** Bug fix: "mandos-monitor" now really redraws screen on Ctrl-L.
 
14
** Now requires Python 2.7.
 
15
 
 
16
Version 1.6.7 (2014-07-17)
 
17
* Client
 
18
** Bug fix: Now compatible with GPGME 1.5.0.
 
19
** Bug fix: Fixed minor memory leaks.
 
20
* Server
 
21
** "mandos-monitor" now has verbose logging, toggleable with "v".
 
22
 
 
23
Version 1.6.6 (2014-07-13)
 
24
* Client
 
25
** If client host has an SSH server, "mandos-keygen --password" now
 
26
   outputs "checker" option which uses "ssh-keyscan"; this is more
 
27
   secure than the default "fping" checker.
 
28
** Bug fix: allow "." in network hook names, to match documentation.
 
29
** Better error messages.
 
30
* Server
 
31
** New --no-zeroconf option.
 
32
** Bug fix: Fix --servicename option, broken since 1.6.4.
 
33
** Bug fix: Fix --socket option work for --socket=0.
 
34
 
 
35
Version 1.6.5 (2014-05-11)
 
36
* Client
 
37
** Work around bug in GnuPG <http://bugs.g10code.com/gnupg/issue1622>
 
38
** Give better error messages when run without sufficient privileges
 
39
** Only warn if workaround for Debian bug #633582 was necessary and
 
40
   failed, not if it failed and was unnecessary.
 
41
 
 
42
Version 1.6.4 (2014-02-16)
 
43
* Server
 
44
** Very minor fix to self-test code.
 
45
 
 
46
Version 1.6.3 (2014-01-21)
 
47
* Server
 
48
** Add systemd support.
 
49
** For PID file, fall back to /var/run if /run does not exist.
 
50
* Client
 
51
** Moved files from /usr/lib/mandos to whatever the architecture
 
52
   specifies, like /usr/lib/x86_64-linux-gnu/mandos or
 
53
   /usr/lib64/mandos.
 
54
 
 
55
Version 1.6.2 (2013-10-24)
 
56
* Server
 
57
** PID file moved from /var/run to /run.
 
58
** Bug fix: Handle long secrets when saving client state.
 
59
** Bug fix: Use more magic in the GnuTLS priority string to handle
 
60
   both old DSA/ELG 2048-bit keys and new RSA/RSA 4096-bit keys.
 
61
* Client
 
62
** mandos-keygen: Bug fix: now generate RSA keys which GnuTLS can use.
 
63
                  Bug fix: Output passphrase prompts even when
 
64
                  redirecting standard output.
 
65
 
 
66
Version 1.6.1 (2013-10-13)
 
67
* Server
 
68
** All client options for time intervals now also take an RFC 3339
 
69
   duration.  The same for all options to mandos-ctl.
 
70
** Bug fix: Handle fast checkers (like ":") correctly.
 
71
** Bug fix: Don't print output from checkers when running in
 
72
   foreground.
 
73
** Bug fix: Do not fail when client is removed from clients.conf but
 
74
   saved settings remain.
 
75
** Bug fix: mandos-monitor now displays standout (reverse video) again
 
76
   using new version of Urwid.
 
77
** Bug fix: Make boolean options work from the config file again.
 
78
** Bug fix: Make --no-ipv6 work again.
 
79
** New default priority string to be slightly more compatible with
 
80
   older versions of GnuTLS.
 
81
* Client
 
82
** Bug fix: Fix bashism in mandos-keygen.
 
83
** Default key and subkey types are now RSA and RSA, respectively.
 
84
   Also, new default key size is 4096 bits.
 
85
 
 
86
Version 1.6.0 (2012-06-18)
 
87
* Server
 
88
** Takes new --foreground option
 
89
** Init script supports new "status" action.
 
90
* Client
 
91
** Now uses all interfaces by default; the --interface option can
 
92
   still be used to restrict it, and the argument to --interface (as
 
93
   well as the $DEVICE environment variable for the network hooks) is
 
94
   now a comma-separated list of interfaces to use.
 
95
 
 
96
Version 1.5.5 (2012-06-01)
 
97
* Server
 
98
** Server takes new --socket option
 
99
 
 
100
Version 1.5.4 (2012-05-20)
 
101
* Server
 
102
** Bug fix: Regression fix: Make non-zero approval timeout values work.
 
103
** Bug fix: Regression fix: Allow changing the Timeout D-Bus property.
 
104
** Fall back to not bind to an interface if an invalid interface name
 
105
   is given.
 
106
** Removed support for undocumented feature of using plain "%%s" in
 
107
   "checker" client option.
 
108
** Old D-Bus interface are now marked as deprecated.
 
109
** mandos-monitor: Bug fix: show approval timers correctly.
 
110
** mandos-ctl: Show "Extended Timeout" correctly, not as milliseconds.
 
111
 
 
112
Version 1.5.3 (2012-01-15)
 
113
* Server
 
114
** Add D-Bus property se.recompile.Client.LastCheckerStatus and use it
 
115
   in mandos-monitor.
 
116
* Client
 
117
** Fix bugs in the example "bridge" network hook.
 
118
 
 
119
Version 1.5.2 (2012-01-08)
 
120
* Server
 
121
** Removed D-Bus signal se.recompile.Mandos.NewRequest() added in
 
122
   1.5.0.  It was buggy and was of questionable utility.
 
123
 
 
124
Version 1.5.1 (2012-01-01)
 
125
* Server
 
126
** Include intro(8mandos) manual page, missing since migration from
 
127
   README file in version 1.4.0.
 
128
 
 
129
Version 1.5.0 (2012-01-01)
 
130
* Client
 
131
** Network hooks.  The Mandos client can now run custom scripts to take
 
132
   up a network interface before the client is run.  Three example
 
133
   scripts are provided: "wireless", "openvpn", and "bridge".
 
134
   To facilitate this, the client now prefers network interfaces which
 
135
   are up (if any) over all other interfaces.
 
136
* Server
 
137
** Persistent state.  Client state is now saved between server
 
138
   restarts.
 
139
** clients.conf file can now contain "enabled" setting for clients.
 
140
** Bug fix: Fix rare crash bug.
 
141
** Bug fix: Send corrent D-Bus type in PropertyChanged for
 
142
   "ApprovalDelay", "ApprovalDuration", "Timeout", and
 
143
   "ExtendedTimeout".
 
144
** mandos-ctl: Bare numbers as arguments are taken to be milliseconds.
 
145
** Bug fix: mandos-ctl --secret option now works.
 
146
** New D-Bus signal: se.recompile.Mandos.NewRequest(s).
 
147
 
 
148
Version 1.4.1 (2011-10-15)
 
149
* Server
 
150
** Make D-Bus properties settable again, and handle checkers
 
151
   for disabled clients correctly.
 
152
* Miscellaneous fixes to "pedantic" Lintian warnings
 
153
 
 
154
Version 1.4.0 (2011-10-09)
 
155
* README file migrated to manual page intro(8mandos).
 
156
* Client:
 
157
** Fixed warning about "rmdir: Directory not empty".
 
158
* Server:
 
159
** Default values changed: timeout 5 minutes, interval 2 minutes.
 
160
** Clients gets an expiration extension when receiving a password,
 
161
   controlled by new "extended_timeout" setting.
 
162
** New domain name: "fukt.bsnet.se" changes to "recompile.se".  This
 
163
   also affects the D-Bus bus and interface names (old names still
 
164
   work).  Users should start using the new names immediately.
 
165
** New D-Bus Client object properties "Expires" and "ExtendedTimeout";
 
166
   see DBUS-API for details.
 
167
 
 
168
Version 1.3.1 (2011-07-27)
 
169
* Client:
 
170
** Client now retries all Mandos servers periodically.
 
171
** Work around Debian bug #633582 - fixes "Permission denied" problem.
 
172
 
 
173
Version 1.3.0 (2011-03-08)
 
174
* Server:
 
175
** Updated for Python 2.6.
 
176
* Client:
 
177
** Bug fix: Make the password-prompt plugin not conflict with
 
178
   Plymouth.
 
179
** Bug fix: Bug fix: update initramfs also when purging package.
 
180
 
4
181
Version 1.2.3 (2010-10-11)
5
182
* Server:
6
183
** Bug fix: Expose D-Bus API also in non-debug mode.